IC 74160 PDF

They are ideal for slowly changing or noisy signals. The count advances as the clock input becomes low on the falling-edge , this is indicated by the bar over the clock label. This is the usual clock behaviour of ripple counters and it means a counter output can directly drive the clock input of the next counter in a chain. For normal use connect QA to clockB to link the two sections, and connect the external clock signal to clockA. For normal operation at least one reset0 input should be low, making both high resets the counter to zero , QA-QD low. Note that the has a pair of reset9 inputs on pins 6 and 7, these reset the counter to nine so at least one of them must be low for counting to occur.

Author:Yorg Sharamar
Country:Cyprus
Language:English (Spanish)
Genre:Business
Published (Last):7 May 2016
Pages:120
PDF File Size:3.50 Mb
ePub File Size:1.24 Mb
ISBN:250-5-82250-598-7
Downloads:27388
Price:Free* [*Free Regsitration Required]
Uploader:Mazuzil



Do you already have an account? IC pinout diagram — Integrated Circuits Jun 15, 5. Jun 15, 3. Check with exact datasheet to ensure correct wiring, the provided is for explanatory uses only. Heart Rate Monitors Wearable fitness technology has come a long way since the basic pedometers of yesteryear. Posted by rkobasketball in forum: During normal operation, such as counting mode, the clear input must be kept high either directly or through a pull up resistor. Jun 15, 6. Feb 19, 4, By wiring more than one 74LS together cascadingit is possible to make higher count lengths powers of ten.

Jun 15, 2. Your name or email address: Returning the load input to logical 1 high will resume the counter now starting from the new preloaded value. Jun 15, This counter IC can be cleared set to all zero at any time, by bringing the clear input to logical zero ground. How Self-Healing Electronics Could Change Everything, from Smartphones to Space Stations A team of engineers at the University of California have created a conductive mixture that, when printed, can self-heal if damaged.

The inputs ABCD is to load the starting value. I guess if you connect them to ground Lowthen you load a starting value of Jun 15, 8. Jun 15, 9. Help with decade counter Posted by CaptainPrice in forum: Jun 15, 7. Nov 22, 76 0. So the counter goes: No, create an account Jun 15, 1. Jun 15, 4.

CRUCIFICTION CRUCIFIXION PDF

Subscribe to RSS

Voodoorisar Jun 15, 2. Quote of the day. This counter IC can be cleared set iv all zero at any time, by bringing the clear input to logical zero ground. The inputs ABCD is to load the starting value. During normal operation, such as counting mode, the clear input must be kept high either directly or through a pull up resistor. Jun 15, 5. This part is readily available from electronics suppliers in various packages and pinouts.

ELISABETH FAYT PDF

Display Clock Circuit 74160 Counters

.

Related Articles